Main Article Content
Abstract
The response of typical low-rise steel building frames designed by the "Type 2 Consctruction" method to moderate earthquakes is examined. Such frames are often identified by large girders, small columns, and semi-rigid connections. The simple methods underlying the Type 2 design approach do not permit realistic consideration of the frame response to either static or dynamic loads. In this paper, typical flexibly connected Type 2 fiames will be analyzed for seismic resistance with the methods recommended by the 1988 Uniform Building Code. The results indicate that these Type 2 frame possess adequate strength, but may not have adequate lateral stiffness for moderate seismic loads
Article Details
How to Cite
-, H. (2016). Seismic Response of Flexibily-Connected Steel Frames. Unisia, (15), 109–115. https://doi.org/10.20885/unisia.v0i15.5305