The response of typical low-rise steel building frames designed by the "Type 2 Consctruction" method to moderate earthquakes is examined. Such frames are often identified by large girders, small columns, and semi-rigid connections. The simple methods underlying the Type 2 design approach do not permit realistic consideration of the frame response to either static or dynamic loads. In this paper, typical flexibly connected Type 2 fiames will be analyzed for seismic resistance with the methods recommended by the 1988 Uniform Building Code. The results indicate that these Type 2 frame possess adequate strength, but may not have adequate lateral stiffness for moderate seismic loads
Article Details
License
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.
How to Cite
-, H. (2016). Seismic Response of Flexibily-Connected Steel Frames. Unisia, (15), 109–115. https://doi.org/10.20885/unisia.v0i15.5305